News
-
How often is a diesel generator set maintained
1. The maintenance cycle of the air filter of the diesel generator set shall be maintained once for 50 hours. 2. Repair and maintain the battery every 50 hours. 3. The maintenance cycle of the belt is once every 100 hours. 4, the radiator maintenance for every 200 hours of operation. 5, lubricati...Read more -
11 ways to start a diesel generator that you fear the most?
Generators are used in many places in our life, such as hospitals, communications, mining, banks, oil fields, railway stations and other places related to people’s livelihood.Generators are essential equipment, both for providing electricity and as a reserve.The proper starting of the generator c...Read more -
129th CANTON FAIR Live Stream schedule
https://ex.cantonfair.org.cn/pc/zh/exhibitor/4ab00000-005f-5254-a3ee-08d7ed79f4ad/liveRead more -
What are the cautions for high power diesel generators?
First of all, don’t overload the high-power diesel generator. The diesel engine should be maintained regularly for oil change air filter oil filter, and the generator should pay attention to dust removal. If it is elastic coupling, pay attention to check the wear condition of small elastici...Read more -
Pay attention to the purchase of diesel generator set!
Now many bad vendors and buyers falsely report the brand and power of products in order to make huge profits! Lead to customers for diesel product brand and performance as a big misunderstanding! For example, the brand and performance of 100kW generator are all fake. So how to purchase generator ...Read more -
The generator set shall not operate for a long time under the following 10 conditions
Basic knowledge of diesel generator 1. What are the six systems included in the basic equipment of a diesel generator set? A: (1) Oil lubrication system; (2) Fuel system; (3) Control and protection system; (4) Cooling and cooling system; (5) Exhaust system; (6) starting system; 2. Why do you advi...Read more -
Two 1000KVA containerized Keypower generators are ready to ship
Read more -
Do you treat your generators with correct “DRINK” under such cold wave?
Read more -
Simple and elegant appearance. ☑ Neat circuit wiring. ☑ Methodical assembly. ☑ Strict pre-shipment testing. ☑ What you can see and what you can’t see, we will handle it for you
Read more -
What are some common mistakes in diesel generator operation?
Diesel generator error Operation 1: When the diesel engine runs with insufficient oil, the oil supply of each friction pair surface will be insufficient due to insufficient oil supply, resulting in abnormal wear or burn.To this end, diesel generator before starting and diesel engine running proce...Read more -
2x500KVA Cummins generator with parallel control had ready for shipment. Household generator is very popular,Keypower are fighting to meet partner’s lead time.
Read more -
2200 kw keypower load bank is in use in Singapore
Read more