Company News
-
What is the transient load performance of the motor?
When the motor is operating, its original KVA (operating KVA) exceeds its operating KVA. This is because of the raw surge voltage required to start the motor. The original load requirements are higher, which in turn causes the terminal voltage to drop sharply. The transient response and recovery ...Read more -
Scania engineer visits Keypower for technical support
Scania engineer visits Keypower for technical support. We’re the OEM partner of Scania whose engines feature super low fuel consumption, long overhaul interval and 100% biogas support which all contribute to its very low cost of ownership, it’s a go-to choice for sectors like rental, ...Read more -
Keypower load bank 100KW to 600KW
-
Two units of 600kVA generators are being tested in parallel, powered by Scania, with Leroy Somer alternators, containerized canopy.
-
500 kva Perkins/Leroy Somer generator with heaters for coolant, fuel tank, fuel line and filters
-
Another 44pcs of generators powered by Fawde engines, keypower alternator. 3 stacks loading—44pcs/40HC.
-
Noise test for 313kva with Cummins engine
-
400kVA Cummins genset with new color, open type.
-
Precautions for generator set installation
1. The installation site of diesel generator set shall be well ventilated, with sufficient air inlet at the generator end and good air outlet at the diesel engine end. The air outlet area shall be more than 1.5 times larger than the water tank area. 2. The surroundings of the generator installati...Read more -
How often is the diesel generator set maintained
1. The maintenance cycle of air filter of diesel generator set is once every 50 hours. 2. The battery shall be maintained every 50 hours. 3. The maintenance cycle of the belt is once every 100 hours of operation. 4. The radiator shall be maintained every 200 hours of operation. 5. The lubricating...Read more -
How to handle the diesel generator set?
Diesel generator set is divided into fixed type and mobile type. Fixed diesel generator sets sometimes involve the problem of handling due to changing places. So how to handle the diesel generator set? The following is the introduction of wing power. First of all, we need to vent the diesel gener...Read more -
what is load bank?
A load bank is a device designed to provide electrical loads for testing various power sources. Load banks are also used to provide additional loads to diesel generators to ensure the engine fully consumes the fuel in the combustion process, reducing “wet stacking” problems. The load bank develop...Read more