| GENSET MODEL | Genset Specification | Engine Specification | Alternator Model | |||||||
| KVA | Cons 100% (L/H) | dB(A) @7m | Tank (L) | Model | Cyl. | Gov. | Asp. | |||
| ESP | PRP | |||||||||
| KP-C94P | 100 | 94 | 22 | 70 | 300 | 6BT5.9-G1 | 6 | M | TC | KP274C | 
| KP-C100S | 100 | 94 | 22 | 70 | 300 | 6BT5.9-G1 | 6 | M | TC | KP274C | 
Voltage regulation
Voltage regulation maintained within ±0.5% as follow:
● Power factor Between 0.8~1.0 lag
● From no load to full load, any steady load
● Speed droop variation under 4.5%
Frequency/Speed undulation
● Change load from 0-100%, Frequency/Speed Droop Ratio within 5%.
● Load from 25-100%, any steady load Frequency/Speed undulation within 0.25%
Effect factor of telecom
● TIF( MA MG1-22) better than 50
● THF( BS EN60034) better than 2%


DIESEL GENERATOR SPECIFICATIONS
1. Powered by reliable engines
 2. Branded alternator
 3. Open type, silent type or super silent type generator
 4. ISO, CE certified
GENERATOR SPECS:
 Rated output: 2 to 2,000kW/2 to 2,500kVA
 Rated voltage: L-N 110 to 277V, L-L 220 to 480V
 Rated frequency: 50/60Hz
ENGINE:
 Brands: Cummins, Perkins,  Deutz, Doosan, Mitsubishi, Kubota, Yanmar or other reliable Chines eengines such as Fawde and Laidong.
 Cooling method: closed water-cooled or air-cooled
 Starting method: electric start or recoil start
 Rated speed: 1,500/1,800/3,000/3,600rpm
 Noise level: 56 to 75dB, 7 meters away
ALTERNATOR:
 Brands: Stamford, Leroy Somer, Mecc Alte and Keypower brushless alternator
 Rated output: 8 to 2,000kW/10 to 2,500kVA
 Rated voltage: L-N 110 to 277V, L-L 220 to 480V
 Rated frequency: 50/60Hz
 Phase: 3-phase, 4-wire or 1-phase, 2-wire
 Connection: y or other type connection
 Rated speed: 1,500/1,800rpm
 Excitation: harmonic excitation or phase compound or brushless
 Voltage regulation: AVR automatic
 1.0% voltage regulation in static conditions (maximum)
 Protection class: IP23
 Control panel: Deepsea, ComAp, Keypower
THE PANEL IS PROVIDED WITH:
 Standard engine instrumentation
 Voltmeter with selector switch
 Ammeter with selector switch
 Frequency meter
 Current transformers
 MCB of suitable rating with overload and short-circuit protection
 Optional with AMF control panel or with ATS (automatic transfer switch)
APPLICATIONS:
 With advanced reasonable structure, high efficiency, low vibration and noise, smooth running, high reliability, easy handling, KEYPOWER generators are widely used in national defense, telecommunications, construction site, commercial buildings, industrial and mining sites, oil fields, roads, ports, villas, banks.