Industriella nyheter

  • The role of lubricating oil

    The role of lubricating oil

    During the operation of mechanical equipment, friction generates a large amount of heat. Without the protection of lubricating oil, friction between mechanical parts can lead to increased wear and even damage to the equipment. The main function of lubricating oil is to form a lubricating film bet...
    Läs mer
  • How does the generator manufacturer adjust the gas distribution phase of the 400KW diesel generator set?

    How does the generator manufacturer adjust the gas distribution phase of the 400KW diesel generator set?

    The gas distribution phase of the 400KW diesel generator set is the crankshaft rotation angle corresponding to the opening and closing time of the engine’s intake valve and exhaust valve according to the engine’s working cycle, which is called the gas distribution phase angle, which i...
    Läs mer
  • The oil analysis method, infrared temperature measurement method and diesel engine mechanical fault diagnosis technology have their own advantages

    The oil analysis method, infrared temperature measurement method and diesel engine mechanical fault diagnosis technology have their own advantages

    The main diagnostic techniques for diesel engine mechanical faults include vibration method, thermal parameter analysis method, oil analysis method, infrared temperature measurement method, etc.   (1) Thermodynamic parameter analysis method: mainly detects the performance parameters of diesel eng...
    Läs mer
  • How to maintain generator set temperature

    How to maintain generator set temperature

    Diesel generators are essential equipment for enterprise backup power. The working temperature of the generator set is directly related to the quality of power delivered by diesel generators. Because the moving parts of diesel generator equipment are easily deformed and damaged at high temperatur...
    Läs mer
  • Classification of generator set, connection and difference between gasoline generator and diesel generator

    Classification of generator set, connection and difference between gasoline generator and diesel generator

    Diesel generator and gasoline generator use different kinds of  fuel. The fuel for gasoline generator is gasoline , which has strong flammability and volatility, and the quality is improved after ignition by the ignition plug. Therefore, gasoline generators with small size and have strong explosi...
    Läs mer
  • How to perform diesel generator maintenance? 5 tips to ensure stable operation at all times

    How to perform diesel generator maintenance? 5 tips to ensure stable operation at all times

    Tip 1 – Change the oil regularly   The most important aspect of diesel generator maintenance is to change the oil regularly, just like changing the oil in a vehicle. We recommend changing the engine oil every 50 to 200 hours, depending on a variety of factors. Some factors that affect the fr...
    Läs mer
  • Generator protection configuration principle

    Generator protection configuration principle

    1. For 300MW and above steam turbine generator transformer units, double fast protection shall be installed, that is, generator longitudinal differential protection, transformer longitudinal differential protection and generator transformer unit common longitudinal differential protection; When t...
    Läs mer
  • Precautions for generator set installation

    Precautions for generator set installation

    1. The installation site of diesel generator set shall be well ventilated, with sufficient air inlet at the generator end and good air outlet at the diesel engine end. The air outlet area shall be more than 1.5 times larger than the water tank area.   2. The surroundings of the generator ins...
    Läs mer
  • Precautions for use of diesel generator set

    Precautions for use of diesel generator set

    The diesel generator set must be operated by personnel who are familiar with the unit structure and master the safety operation procedures. New or newly overhauled diesel units shall undergo 60 hours of running in as required, and necessary maintenance shall be done. Before the new or long-term u...
    Läs mer
  • Five reasons for poor heat dissipation of generator

    Five reasons for poor heat dissipation of generator

    The operating temperature of the generator set is very important. It is necessary to maintain it within a suitable range to ensure the working efficiency of the unit. However, in the actual use process, overheating is easy to occur. Overheating is actually caused by poor heat dissipation of the u...
    Läs mer
  • How to remove dirt from generator water tank

    How to remove dirt from generator water tank

    The diesel generator has been used for a long time, which will inevitably cause wear on various parts. For the generator water tank, the scale in the water tank will not only affect the heat dissipation effect of the generator, but also reduce the service life of the diesel engine. Therefore, Suz...
    Läs mer
  • Hur hanterar man dieselgeneratorn?

    Hur hanterar man dieselgeneratorn?

    Diesel generator set is divided into fixed type and mobile type. Fixed diesel generator sets sometimes involve the problem of handling due to changing places. So how to handle the diesel generator set? First of all, we need to vent the diesel generator set before handling it. Remove the relevant ...
    Läs mer