bank mbukak iku piranti dirancang kanggo nyedhiyani kathah electrical Testing macem-macem sumber daya, Including Engine Generators, baterei Systems, UPS Systems, Inverters, Ground Power Unit, Auxiliary Power Unit, Aircraft Power Generators, Generators Angin, lan Banyu Generators etc.
Load testing bank bakal irit wektu lan dhuwit ing roto dawa. Iku carane sampeyan nemtokake status operasi sistem daya utama. Iku uga carane ngleksanani sistem serep kanggo mesthekake padha bakal kasedhiya nalika katimbalan. Mbukak Testing ing wiwitan-up lan sak commissioning lan pangopènan bakal nemokake kahanan masalah sadurunge padha njembarake lan sabab downtime.
Resistive, induktif, capacitive resistive / induktif digabungake
Ya, nanging HFS kasedhiya punika 1/6 kapasitas Testing dirating.
Ya. Multiple Load Banks bisa diselarasake kanggo test siji generator nanging siji Load Bank ora bisa kanggo nyoba macem-macem generator ing wektu sing padha.
Kita Load Banks sing kanggo Applied ngendi dhuwur ≤2500m dpl,
suhu sekitar ing -15 ℃ ~ 55 ℃ lan asor relatif ≤98%.
Contone, KPLB-500 @ 400V bisa nyoba 500kw lengkap @ 400V, lan derating kanggo 165kw mung @ 230V 3 phase. voltase Dual KPLB-500 bisa nyoba 500kw lengkap @ 400V lan @ 230V.
Penggerak tester 8961 digunakake kanggo recalling data saka generator sing Testing. Banjur bisa nggawe laporan test lan formulir gelombang sine. Iku apik kanggo Produsèn generator lan project commissioning.
jinis standar ora weatherproof, nanging discharge online pilihan pipa lan konektor cam-kunci bisa cekap ing kanggo ngaktifake weatherproof.
jinis standar ora ndhukung, nanging pilihan programmable Mitsubishi PLC bisa cekap kanggo ndhukung remot ngawasi lan kontrol ing laptop.